3.2. Preparing the “Cardio domain” page for consultation3.2. Preparing the “Cardio domain” page for consultation3.2. Preparing the “Cardio domain” page for consultation3.2. Preparing the “Cardio domain” page for consultation
  • Book a demo
  • CleverLab
  • Stressonika
    • Use cases
  • Docs
  • Contacts
  • EN
✕

CleverPoint 4 User Manual

16
  • Introduction
    • Customer Support
    • Regulatory Compliance
    • Warranty and Copyright
  • Product Information
    • Product information
    • Technical specifications
    • Application compatibility
    • Safety precautions
    • Maintenance
  • Getting Started
    • Kit contains
    • Equipment Check
    • Types of CleverPoint 4 Indications
    • Charging your CleverPoint 4
    • Turning CleverPoint 4 on/off
    • First time Wi-Fi setup
    • Connecting CleverMask to the VR Headset
    • Connecting the ECG cable to CleverPoint 4

Stressonika - Guide for Working with raw ECG data

20
  • Introduction
  • Chapter 1. General points.
    • General points
  • Chapter 2. Cardio domain
    • Cardio domain
    • Sector. 1
    • Sector. 2
    • Sector. 3
    • Sector 4
    • Sector 5
    • Sector 6
    • Sector 7
    • Sector 8
  • Chapter 3. Cardio domain: examples
    • Cardio domain: examples
    • 3.1. ECG recording quality
    • 3.2. Preparing the “Cardio domain” page for consultation
    • 3.3 Viewing the “Cardio domain” page during consultation (Example 1)
    • 3.4 . Viewing the “Cardio domain” page during consultation (Example 2)
    • 3.5. Viewing the “Cardio domain” page during consultation (Example 3)
    • 3.6 . Viewing the “Cardio domain” page during consultation (Example 4)
    • 3.7. Viewing the “Cardio domain” page during consultation (Example 5)
    • 3.8. The “Cardio domain” page. Conclusion.

CleverPoint View Data v2.15 User Guide

55
  • Introduction
    • Introduction
  • 0. Fundamentals of Electrophysiology for Beginners
    • 0.1. What Are Physiological Signals?
    • 0.2. Autonomic Nervous System (ANS)
    • 0.3. Emotions and the Brain
    • 0.4. Electrodes and Their Placement in the CleverPoint Setup
  • 1. General Principles of Signal Processing
    • 1.1. Basic Transformations
    • 1.2. Marking and Trim
    • 1.3. CAR (Common Average Reference)
    • 1.4. Denoise (Blink Artifact Suppression)
    • 1.5. Normalize
    • 1.6. IMF (Empirical Mode Decomposition)
    • 1.7. Filtering
    • 1.8. Power vs Amplitude
    • 1.9. Epoch
  • 2. “Summary” Interface
    • 2.1. Purpose
    • 2.2. Controls
    • 2.3. Graphs
    • 2.4. Data Export
  • 3. “Time Domain” Interface
    • 3.1. Purpose
    • 3.2. Controls
    • 3.3. Signal Display
    • 3.4. Signal Transformations
  • 4. “Frequency Domain” Interface
    • 4.1. Purpose
    • 4.2. Interface Structure
    • 4.3. Controls
    • 4.4. Spectral Analysis Methods
    • 4.5. Channel Correlation
    • 4.6. Time Series
  • 5. “Power Domain” Interface
    • 5.1. Purpose
    • 5.2. “Power by sections” Mode
    • 5.3. “Between-channel interactions” Mode
    • 5.4. Frequency-Band Graphs
  • 6. “Coherence” Interface
    • 6.1. Purpose
    • 6.2. Controls
    • 6.3. Coherence Calculation Method
    • 6.4. Display
    • 6.5. Interpretation
    • 6.6. Use in Research
  • 7. “Emotional State” Interface
    • 7.1. Purpose
    • 7.2. Interface Structure
    • 7.3. Controls
    • 7.4. Emotion Calculation Method
    • 7.5. Display
    • 7.6. Section Selection
  • 8. “Cardio Domain” Interface
    • 8.1. Purpose
    • 8.2. Interface Structure
    • 8.3. Controls
    • 8.4. Extraction of RR Intervals
    • 8.5. HRV Parameters
    • 8.6. Visualization
    • 8.7. Data Export
  • 9. Conclusion
    • Conclusion
    • 9.1. Recommendations for Use
    • 9.2. Additional Resources
    • 9.3. Beginner’s Guide
View Categories
  • Home
  • Docs
  • Stressonika - Guide for Working with raw ECG data
  • Chapter 3. Cardio domain: examples
  • 3.2. Preparing the “Cardio domain” page for consultation

3.2. Preparing the “Cardio domain” page for consultation

2 min read

We tactfully yet persistently recommend that you conduct consultation based on the report, emphasizing (illustrating, confirming, accentuating, proving, etc.) your conclusions (reasoning, findings, recommendations, assumptions, etc.) with the respondent’s data displayed on the “Cardio domain” page. Figure 3.9 shows a sample, in our view, of how this page should look for consultation. All subsequent illustrations will correspond to the respondent’s primary data visualized in this figure.

Figure 3.9. “Cardio domain” page prepared for consultation

This page will also be the main one in the work of researchers whose interests are related to heart rate variability.

How the image in Sector 4 is formed has already been discussed. It remains only to clarify the graph of Sector 8. For this, it will be necessary to return to the information in Chapter 2 devoted to this sector (Table 2; Figs. 2.27 and 2.28). From Table 2 it can be seen that, for most indicators, the scientific component predominates. For assessing the respondent’s functional state, the greatest interest is HR (HR on the graph) and the level of relaxation (Relaxation). In Figs. 2.27 and 2.28, a heart-rate graph is shown as an example. However, it was previously stated that the RR interval of Sector 5 is the inverse of HR: the smaller the RR interval (a decrease of the graph in Sector 5), the higher the HR (an increase of the graph in Sector 8), and vice versa. This relationship is illustrated separately in Fig. 3.10. Essentially, these graphs reflect the same thing, being in mirror symmetry. When commenting on the CIG, one rather quickly gets used to speaking in terms of HR. Therefore, displaying the HR graph separately in Sector 8 is of little informative value, unlike the relaxation dynamics graph, which we recommend using during consultation.

Figure 3.10. Interdependence of the graphs of Sector 5 and Sector 8 if heart rate values are displayed on the latter

To display the relaxation dynamics graph as shown in Fig. 3.9, a number of manipulations should be performed, which are described in Chapter 2 in the corresponding advisory section: reset all graphs, activate the “Relaxation” graph, scale vertically, and smooth (if necessary) by the number of averaged points of the recorded primary data (in our example, 40 points).

We have prepared the “Cardio domain” page, opened the report, and are now ready for consultation.

Updated on 01.03.2026

What are your Feelings

  • Happy
  • Normal
  • Sad

Share This Article :

  • Facebook
  • X
  • LinkedIn
  • Pinterest
3.1. ECG recording quality3.3 Viewing the “Cardio domain” page during consultation (Example 1)

Our mission

Our mission is to develop products that heighten user awareness of the pivotal role physiology plays in personal and professional endeavors.

We strive to empower our users with the tools to effectively manage stress, prevent burnout, and optimize their well-being.

Contacts

CleverPoint Team - 133, Domaniewska 17/19 Warsawa, Poland, 02-672


+48 578 202 208
[email protected]


All rights reserved. CleverPoint